Research published in Journal of Shanghai Jiao Tong University (Science) has proposed a new method for lung image registration named Dlung. Dlung is an unsupervised few-shot learning-based diffeomorphic lung image registration, which can help construct respiratory motion models based on limited data with both high speed and high accuracy, offering a more efficient method for respiratory motion modeling.
Respiratory motion modeling is an essential technique in imaging technology for the analysis of thoracic organs such as lungs with respiratory motion. It offers important references for targeting tumors by radiotherapy while avoiding damage to normal tissues during lung cancer treatment.
Lung image registration, the process of constructing a dense correspondence between lung image pairs, is critical for respiratory motion modeling. Among all the current methods for lung image registration, unsupervised learning-based methods have gained huge interest as they can compute the deformation without the requirement of supervision.
However, there are two drawbacks in the current unsupervised learning-based methods: one is that they cannot handle problems with limited data; the other is that they lack diffeomorphic (topology-preserving) properties, especially when large deformation exists in lung scans.
Aiming at these two problems, the researchers proposed the method Dlung which solves the problem of limited data via fine-tuning techniques and realizes diffeomorphic registration by the scaling and squaring method. Compared with baseline methods elastix, SyN, and VoxelMorph, Dlung achieves the highest accuracy with diffeomorphic properties when applied in the registration of 4D images.
“Dlung constructs accurate and fast respiratory motion models with limited data,” explained Peizhi Chen, the first author of this research, “we believe that it has a wide application prospect in image-guided radiotherapy when treating lung cancer in the future.”
More information:
Peizhi Chen et al, Dlung: Unsupervised Few-Shot Diffeomorphic Respiratory Motion Modeling, Journal of Shanghai Jiaotong University (Science) (2022). DOI: 10.1007/s12204-022-2525-3
Provided by
Shanghai Jiao Tong University Journal Center
Citation:
Dlung: A novel method for lung image registration (2024, January 7)
retrieved 7 January 2024
from https://medicalxpress.com/news/2024-01-dlung-method-lung-image-registration.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.